Fuji Electric green data centers


1.We are helping to reduce the impact on the environment by using high-efficiency equipment for energy-saving electric power usage and air conditioning, and by using visualization to propose energy optimization.

2.We have an abundant line-up of solutions for constructing your green data center.

3.We offer a one-stop solution from design through construction.

Applicable to all types of data centers: 

modular type

Modular Data Center (Basic configuration)

Main component specifications

■Server block basic module

80 server racks of storage, Server load: 400kW(sever unit average load: 5kW)

Smallest unit: 10 server racks

Robust seismic performance, up to 1000 gal

■Indirect outside air conditioning unit

No concern about dust such as PM2.5, SOX or NOX

Year-round operation possible

Utilizes high-insulation housing

■UPS block

500kVA UPS, high efficiency of 96.5%

Standby redundancy operation with the common UPS building

Example of application to a container type data center
Based on the container enclosure, the hardware required for the data center is assembled as one package.
Configuration
■Server container (1 to 8 racks of storage)

Sever average load: 12.5kW
■Air conditioner : 4 units

F-COOL NEO cooling capacity: 25kW
■Incoming panel

Example of application to a building type data center

Example of partitioning part of the floor, in a building application

■Compatible with various types of floors

■Can be expanded in phases with short delivery time

High efficiency Large capacity UPS7000HX-T4
High efficiency

Adopting RB-IGBT, achieve high efficiency, 96.5%
Space-saving

Footprint is 35% reduced by reducing number of parts and minimizing the parts.
Scalable

Unit Capacity is 500kVA (PF=0.9, 450kW).

8 units can be placed in parallel at the maximum and maximum capacity will be 4000kVA.

Indirect outside air conditioning unit F-COOL NEO

Energy-saving cooling method using outside air indirectly

Less Infrastructure

Water supply not required for cooling water or vaporization Necessary infrastructure is only electric power

Built-in compressor type refrigerator

Utilization of outside air with hybrid system

– Annual rated cooling power of 25 kW and 40 kW

– Copes with high-humidity environments

Utilization of outside air energy

Indirect air usage method

Shuts out causes of corrosion from the outdoors Utilization of outside air throughout the year

For Inquiry or RFQ (Request for Quotation) on posted technology solution, please email: gregoriojess@yahoo.com

Jess C. Gregorio

Affiliate Technical Marketing and Project Lead Generation Manager for the Philippine Territory

gregoriojess@yahoo.com

https://jcgregsolutions.wordpress.com/

Driving Leads. Adding Sales.
View story at Medium.com

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s